What cables are used with insulation piercing connectors?

What cables are used with insulation piercing connectors?

Insulation piercing connectors (IPC) are mainly used to make a connection between protected low voltage overhead lines.

There are The 3 main types of LV-ABC are used with insulation piercing conenctors:

  •  Self-supporting LV-ABC lines

The self-supporting system is composed of 4 insulated aluminium conductors. Mechanical strength and nominal cross section of all 4 conductors are identical. The system can consist of additional 1 or 2 insulated aluminium conductors with cross sections of 16 mm2 or 25 mm2as pilot wire or for street lighting.

When straining the line, all 4 conductors are equally loaded. The service lines of all 3 LV-ABC systems are usually also of the self-supporting type, composed of 2 to 4 factory bundled insulated aluminium conductors with cross sections of 16 mm2, 25 mm2 or 35 mm2.

  • LV-ABC lines with insulated neutral messenger

LV-ABC line with insulated neutral messenger wire, also referred to as “French System”, is composed of 3 insulated aluminium phase conductors and 1 neutral messenger of aluminium alloy (mostly Aldrey) also with insulation. The system can consist of additional 1 or 2 insulated aluminium conductors with cross sections of 16 mm2 or 25 mm2 as pilot wire or for street lighting.
Mechanical strength and nominal cross section of the 3 phase conductors are identical. The neutral conductor is at the same time the suspension unit having a higher mechanical strength. When straining the line, only the neutral conductor, as suspension unit, is loaded. 

  • LV-ABC lines with bare neutral messenger

LV-ABC line with bare neutral messenger wire, also referred to as “Finnish System”, is composed of 3 insulated aluminium phase conductors and 1 neutral messenger of aluminium alloy without insulation. The system can consist of additional 1 or 2 insulated aluminium conductors with cross sections of 16 mm2 or 25 mm2 as pilot wire or for street lighting.

Mechanical strength and nominal cross section of the 3 phase conductors are identical. The neutral conductor is at the same time the suspension unit having a higher mechanical strength. When straining the line, only the neutral conductor, as suspension unit, is loaded. 

What models of insulation piercing connectors to use with the ABC cables?

Jera Line offers a range of insulation piercig connectors( IPCs) that are designed to be used with overhead low voltage insulated cable and bare cable connections.

Jera Line produce ZOP series of insulation piercing connectors are designed for use with insulated low-voltage cables, ZOP-57 can be used with self-supporting LV-ABC lines & LV-ABC lines with insulated neutral messenger. Jera Line ZOP series insulation piercing connectors are specifically engineered to pierce the insulation of the cables, providing a reliable and secure electrical connection without the need to strip the insulation.
Jera Line produce ZOP-N series of insulation piercing connectors are designed for LV-ABC lines with bare neutral messenger. The ZOP-2N type connectors are known for their reliability and ease of installation, making them suitable for various electrical installation needs.

Application advantages of Jera Line Insulation piercing connectors?

Jera Line insulation piercing connectors are commonly used in various applications due to the following advantages:

  •  Easy & Fast Installation: Jera Line insulation piercing connectors are designed for easy and quick installation, connect cables without strip or cut cable jacket, saving time and labor costs during cable connections.
  •  Reliable Electrical Connection: Jera Line insulation piercing connectors has powered piercing teeth which allows the current flow through steadily. Jera Line Insulation piercing connectors provide a secure and reliable electrical connection without the need to strip the cable insulation, reducing the risk of errors and ensuring consistent performance.

Read more: How to install insulation piercing connectors?

  •  Cable Types: Jera Line insulation piercing connectors contact bleeds are made by tinned covered AL teeth, they work with a both CU and AL conductors.
  •  Cable Range: Jera Line has full range of overhead cable insulation piercing connectors for 1KV power lines, from 1.4mm2-400mm2.
  •  Weather Resistance&Durability: Jera Line insulation piercing connectors use UV resistant rubber cap and durable polymers material, which are designed to withstand harsh environmental conditions.
  •  Rust and corrosion prevention: Jera Line insulation piercing connectors use stainless steel bolt and washer, which designed to prevent rust and corrosion furring application.
  •  Type test: Jera Line insulation piercing connectors compliance NFC 33-020, EN 50483 type test which made by independent laboratory.

Overall,Jera Line insulation piercing connectors are suitable for outdoor overhead line applications, ensuring long-term performance and reliability.

 Jera Line manufacturer offer a convenient and reliable solution for making secure electrical connections in a wide range of applications.

 